1 Grindon Way Heighington Business Park, Newton Aycliffe, United Kingdom
The pingers are highly configurable and can be custom-made with different ping rates and frequencies as per the client’s specifications. This allows for differentiation between pigs within a pig train and can also be used to extend the battery life. The 600 series pingers are activated once immersed in fluid; thus allowing them to be loaded months in advance of the flooding operation. The pingers are capable of sending acoustic transmissions over distances of several kilometres, dependent upon unit configuration, mounting arrangement and environmental conditions.
The pingers are highly configurable and can be custom-made with different ping rates and frequencies as per the client’s specifications. This allows for differentiation between pigs within a pig train and can also be used to extend the battery life. The 800 series pingers are activated once immersed in fluid; thus allowing them to be loaded months in advance of the flooding operation. The pingers are capable of sending acoustic transmissions over distances of several kilometres, dependent upon unit configuration, mounting arrangement and environmental conditions.
The pingers are highly configurable and can be custom-made with different ping rates and frequencies as per the client’s specifications. This allows for differentiation between pigs within a pig train and can also be used to extend the battery life. The 1200 series pingers are activated once immersed in fluid; thus allowing them to be loaded months in advance of the flooding operation. The pingers are capable of sending acoustic transmissions over distances of several kilometres, dependent upon unit configuration, mounting arrangement and environmental conditions.
The transmitters can be customised as required - for example the transmitter power level can be adjusted to achieve the optimum balance between signal strength and battery life. Additionally different pulse rates allow for differentiation within a pig train. An inherent electromagnetic null spot is detectable using an electromagnetic antenna meaning that the operator can confirm the location of the transmitter to within a few centimetres. This greatly reduces vessel and operational downtime by facilitating the process of locating a stuck pig or confirming if a pig has left the launcher or been successfully received.
The transmitters can be customised as required - for example the transmitter power level can be adjusted to achieve the optimum balance between signal strength and battery life. Additionally different pulse rates allow for differentiation within a pig train. An inherent electromagnetic null spot is detectable using an electromagnetic antenna meaning that the operator can confirm the location of the transmitter to within a few centimetres. This greatly reduces vessel and operational downtime by facilitating the process of locating a stuck pig or confirming if a pig has left the launcher or been successfully received.
The transmitters can be customised at build - for example the pulse rate can be altered to provide the desired battery life and to allow for differentiation within a pig train.
An inherent electromagnetic null spot is detectable using an electromagnetic antenna meaning that the operator can confirm the location of the transmitter to within a few centimetres. This greatly reduces vessel and operational downtime by facilitating the process of locating a stuck pig or confirming if a pig has left the launcher or been successfully received.
The transmitters can be customised at build - for example the pulse rate can be altered to provide the desired battery life and to allow for differentiation within a pig train.
An inherent electromagnetic null spot is detectable using an electromagnetic antenna meaning that the operator can confirm the location of the transmitter to within a few centimetres. This greatly reduces vessel and operational downtime by facilitating the process of locating a stuck pig or confirming if a pig has left the launcher or been successfully received.
Minimal set up is required ensuring that time is not wasted setting up various parameters.
Events are signalled as they occur via a graphical display and high brightness LEDs positioned around the perimeter of the display. The unit logs the time and date of up to 99 events. Logged events can be viewed locally on the display or transmitted remotely.
Events are signalled as they occur via a graphical display and high brightness LEDs positioned around the perimeter of the display. The unit logs the time and date of up to 99 events. Logged events can be viewed locally on the display and reviewed at a later date.