2230 E. 49th Street, Tulsa, United States of America
The most respected and prevalent engine driven cooler design in the gas compression industry. A superior design proven in tens of thousands of installations worldwide.
Advantage Summary
Efficent Forced Draft Design
The advantage of AXH air-coolers EF forced draft, vertical discharge design is that fan handles cool, denser ambient air. As a result, the fan is inherently more efficient requiring less fan horsepower than induced draft coolers handling hot discharge air. Superior air flow further minimizes the recirculation of discharge hot air making it virtually unaffected by variations in wind direction or the location of adjacent equipment.
Sloped Sections with Superior Weight Distribution
The Type EF's design offers combined engine and compressor cooling with multiple stage gas services in a single structure. A primary advantage of the cooler's sloped section arrangement is that it provides greater cooling capacity within a given frame size with a compact “footprint?which in turn reduces the required skid or pad space. The "top (front) heaviness" of an induced draft cooler is also eliminated with the center of gravity located close to the physical center or the cooler, resulting in greater safety and stability in handling.
Drive Options
Normally V-belt driven from the engine or compressor the EF can also be provided with an internal electric motor or other type drives.
Integral Shutters
Adjustable aluminum shutters are a standard feature on most Type EF coolers. Shutters provide superior air-flow characteristics and improved operating efficiency. Individual manual operators with remote linkage or optional air motors provide added temperature control by allowing independent louver adjustment over individual services.
Improved Safety And Maintanence
A forced draft design is generally considered to be safer with the fan working against a positive static head of pressure between the fan and coils. Both fan and bearings are located in cooler ambient air and are easily visible for inspection and easy access for maintenance of all moving components.
Options
Auxiliary louvers, located on the air Inlet side, can provide greater control of fluid outlet temperatures and can be automated. "Soft" quickly removable bug screens, discharge or personnel guards, access ladders and warm air recirculation systems are common optional features.
AXH air-coolers Type FF is a forced draft, multiple-fan, vertical discharge design with a lower profile that is ideal for large HP applications while providing bonus features at a cost that compares favorably to a large single fan vertical discharge cooler
Advantage Summary
Low-profile Design and Narrow Width
The Type FF design is ideal for large HP applications where a single fan cooler is unable to meet the application requirements due to physical size limitations. The lower profile and narrow width can simplify shipping and reduce transportation costs due to special routing or when compared to multiple coolers. Site plan area can often be reduced in multiple unit installations.
Efficient Forced Draft Design
The FF is a forced draft, vertical discharge, multiple-fan design is that it is inherently more efficient in which the fan handles cool, dense ambient air. As a result, the fan requires less fan horsepower than an induced draft cooler.
Multiple-Fan Design Provides Flexibility And Reliability
By using multiple fans with individual plenum chambers each fan bay can be isolated thus offering continued operation in the event of a fan or bearing failure. Fans can also be isolated during cold weather operation to reduce parasite fan HP and provide better air and temperature control. Models range in fan size from 48" to 144" incorporating up to five fans.
Functional Design Cuts Piping Costs
Normal design procedures used in the rating process facilitates piping. This results is nozzle arrangements that reduce piping costs. The design provides for greater accessibility to piping, drive, bearings and coils. The added open, drive-end space makes engine inspection and maintenance easier which can accommodate the installation of other equipment thus maximizing use of skid space. When installed on a common single skid it can eliminate the expense of a separate "T-skid" as well as the inconvenience and costly drive and piping disassembly and field reassembly in many applications.
Drive Options
Although normally V-belt driven from the engine or compressor the Type FF can be provided with an electric motors, hydraulic drives or even small gas engines.
Improved Safety And Maintenance
A forced draft design is considered to be safer with the fan working against a positive static head of pressure between the fan and coils. Both fan and bearings are located in cool ambient air and provide for visual inspection and easy access provided for maintenance of all moving components.
Options
Adjustable aluminum shutters are an option on all Type FF coolers. Shutters with remote linkage provide superior air flow characteristics and improved operating efficiency. Individual manual operators or optional air motors provide temperature control by allowing independent louver adjustment over separate services. Bug screens, hail or discharge/personnel guards, access ladders and warm air recirculation systems are common options.
Advantage Summary
Vertical Discharge Design
The induce draft Type VI design offers combined engine and compressor cooling with multiple stage gas services in a single structure. It minimizes hot air recirculation due to its vertical discharge design and is virtually unaffected by variations in wind direction or the location of adjacent equipment in applications requiring induced draft cooling.
Section Accessibility
The Type VI's design provides greater section accessibility in applications requiring section replacement or change out. All sections are equipped with integral core guards for maximum protection of the exposed sections.
Superior Temperature Control
Adjustable aluminum shutters are an optional feature on all Type VI coolers and are located on the air inlet side of the sections for improved control of fluid outlet temperatures. Manual or automated shutters with remote linkage provide superior air-flow control and improved operating efficiency by allowing independent louver adjustment over separate services.
Drive Options
Normally V-belt driven from the engine or compressor the VI can be provided with an internal electric motor or hydraulic drive.
Inspection And Maintenance
Fan and fan bearings are provided with removable access doors for easy inspection and maintenance while the rear drive bearing is located outside in cooler ambient air for extended operating life. All bearings are serviced by means of remote lubrication fittings.
Options
In addition to louvers located on the air Inlet side, low noise fans, bug screens, discharge or personnel guards, access ladders and occasionally warm air recirculation systems are other options.
Advantage Summary
Multiple services in a single unit
The Type VV is commonly used for gas, lube oil and water cooling applications where recirculation of hot discharge air is not critical. They are available in virtually all fan sizes as small as 24� while their flexibility allows use in a wide range of special applications
Forced or Induced Draft Design
Type VV coolers are available in either a forced (VVF) or induced draft (VVI) configuration with horizontal air flow and can be configured to meet individual installation requirements. Propeller type air-foil fans with either fixed or adjustable pitch result in higher efficiency and lower fan horsepower.
Section Accessibility
The Type VV's design provides greater section accessibility in applications requiring section replacement or change out. All sections are equipped with integral core guards for maximum protection of the exposed sections.
Temperature Control
Adjustable aluminum shutters are an optional feature on all VV models and are located on the air inlet side of the sections in induced draft models for improved control of fluid outlet temperatures. Manual or automated aluminum shutters are available offering superior air-flow control and improved operating efficiency by allowing independent louver adjustment over separate services.
Drive Options
Fans and can be V-belt driven from an engine or compressor or adapted to a variety of drive types -- direct, electric motor or hydraulic.
Inspection and Maintenance
Standard single fan and blower pillow-block bearing assemblies on both fan and idler is normal and assures proper alignment and easy maintenance when engine or compressor driven. Fan and idler bearings are also interchangeable on most standard units. Fans are provided with removable access guards for easy of inspection and maintenance.
Options
In addition to louvers located on the air Inlet or discharge side, low noise fans and bug screens are other options.
Horizontal Designs Provide Flexibility in Remote Installation for Large HP Gas Compression or Process Cooling
Advantage Summary
Remote Installation
The Type ZF are commonly used for large hp or process applications where remote �off skid?installation is required. Structural design ensures optimum sizing of end and center panels to support all dead loads of cooler sections and piping in accordance with API and are designed to withstand 125 mph wind loading. The self-contained design eliminates the need for costly field assembly and reduces transportation costs while meeting the most severe installation requirements.
Forced or Induced Draft Design
AXH air-coolers Horizontal coolers are normally more efficient, forced draft designs but are alternately available in induced draft configurations with higher exit velocities. All are vertical air flow to minimize recirculation of hot discharge air. Models are available with single or multiple fans ranging in sizes from 24?to 192? Their design and size flexibility enables them to be used in a wide range of special applications.
Section Accessibility & Temperature Control
The horizontal Type ZF design provides section accessibility in which all sections are equipped with lifting lugs and core guards for maximum protection of the exposed sections. Manual or automated aluminum shutters are an optional feature on all ZF models. These offer improved control of fluid outlet temperatures and operating efficiency by allowing independent louver adjustment over separate services.
Drive Options
Fans are normally driven by integrally suspended electric motors using HTD or V-belts but can be adapted to a variety of alternate type drives ?right ange gears in larger fan hp applications, internal, direct, engine jack shaft, or hydraulic. All drives are integrally mounted, aligned, and test run prior to shipment.
Inspection and Maintenance
Type ZF coolers offer convenient accessibility to all components with fan, drive and bearings all located in cooler ambient air for increased operating life. For safety and easy maintenance, all units have individually removable fan and drive guards meeting all state and OSHA regulations louvers along including remote lubrication fittings.
Options
Hail guards, bug screens, ladders & platforms, low noise fans, base enclosures and warm air recirculation systems can be provided.